No flame when the burner starts
Breakdown: the boiler is stopped
The burner tried to start, but no flame appeared within the safety time: the oil supply, the ignition or the flame detection is at fault. On the Modulens O AFC-S it is a lockout: the boiler stops, the screen flashes red, and it only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E07.14?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E07.14
The meaning depends on the boiler: find yours below.
No flame after the burner safety time
What our technician checks
- The oil tap, which must be open
- Tightness of the oil supply circuit (no air bubbles in the oil filter)
- Operation of the solenoid valve, replaced if necessary
- Condition and gap of the ignition electrodes, replaced if necessary
- The high-voltage wiring, the earthing and the ignition transformer
- Connection of the detection cell to the burner control and safety box
- Cleanliness of the combustion head mirror and alignment of the detection cell, replaced if necessary
- The recirculation slot, to be closed (see the settings table), then the burner control and safety box