Return too hot or oil pressure
Breakdown: the boiler is stopped
On the Innovens MCA and Modulens G AGC the water returning to the boiler is too hot (STB RETOUR), because of a sensor or water that is not circulating; on the Modulens O AFC (oil) the same code reports an oil pressure out of limits. It is a fault: the boiler stops and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On an Innovens MCA or Modulens G AGC, check that the radiator valves are open, then bleed the air from the cold radiators, starting with the lowest floors.
- On an Innovens MCA or Modulens G AGC, check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show L09?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code L09
The meaning depends on the boiler: find yours below.
STB RETOUR
DEF.PRES.FIOUL
The boilers that show this code
What our technician checks
- The sensor connections
- The sensor, replaced if faulty
- Bleeding the air from the heating system
- Water circulation: direction, pump and valves
- The system water pressure
- Modulens O AFC: the oil pressure