Burner combustion fault
Breakdown: the boiler is stopped
On the MPX2 Compact and Virtuens the boiler reports a combustion fault (electrode, gas supply, air inlet or flue outlet); on the AMC the burner temperature stays away from its setpoint for more than 60 seconds. On AMC, MPX2 Compact and Virtuens boilers it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E04.14?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E04.14
The meaning depends on the boiler: find yours below.
Combustion error
Combustion fault
What our technician checks
- The electrode's electrical connections and condition
- The gas supply pressure
- The gas valve calibration
- The air inlet and the flue terminal
- The electrical supply voltage