AUX zone hot water sensor short-circuited
Blocking: it retries by itself
The domestic hot water temperature sensor of the AUX zone is short-circuited: faulty wiring or connector, a badly fitted or faulty sensor, or a thermostat connected instead of the sensor without the setting it needs. On AMC, AMC Pro Evo, Virtuens and Modulens O AFC-S boilers it is a blocking fault: the boiler interrupts its normal operation and starts again by itself once the cause has been removed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.10.39?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.10.39
The meaning depends on the boiler: find yours below.
T DHW AUX zone clsd
AUX zone domestic hot water temperature sensor short-circuited
AUX zone S short-circ
What our technician checks
- The wiring and connectors between the sensor and the circuit board
- How the sensor is fitted
- The sensor, replaced if faulty
- Parameter CP504, set to off if a thermostat replaces the sensor