Flame lost several times
Breakdown: the boiler is stopped
The burner flame went out several times while running: more than 5 times in 24 hours on the Innovens MCA and Modulens G AGC (gas), where the boiler no longer measures the ionisation current that confirms the flame, and 3 times during one heat demand on the Modulens O AFC (oil). It is a lockout fault: the control panel shows the code and the boiler stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Innovens MCA or Modulens G AGC: check that the boiler's gas tap is fully open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show L36?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code L36
The meaning depends on the boiler: find yours below.
DEF.IONISATION
DEF.DISP.FLAM.
The boilers that show this code
What our technician checks
- Innovens MCA, Modulens G AGC: the ionisation current (flame signal)
- Innovens MCA, Modulens G AGC: whether the gas tap is open
- Modulens O AFC: the cause of the flame losses during the heat demand