Room sensor or thermostat not detected
Blocking: it retries by itself
The boiler expects a room sensor or room thermostat (the device in the room that controls the heating) and does not detect it: it is disconnected, badly connected, or communication with it fails. On AMC Pro Evo, MCR-S, MPX2 Compact and Virtuens boilers it is a blocking fault: the boiler interrupts its normal operation and starts again by itself once the cause has been removed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.00.81?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.00.81
The meaning depends on the boiler: find yours below.
Room sensor missing
Room thermostat disconnected
Room temperature sensor expected but not detected
Room temperature sensor missing
What our technician checks
- The room sensor or thermostat connection
- Operation of the room thermostat (MCR-S)
- The communication bus (MPX2 Compact, Virtuens)
- Setting CP780 = 0 if the thermostat was removed on purpose (MCR-S)
- The circuit board, replaced if needed