Lockout: flue gas pressure too high
Breakdown: the boiler is stopped
The pressure in the flue gas outlet has reached an extreme value too often: on the Modulens O AFC-S the message H02.26 appeared 5 times in 24 hours; on the CFU C the flue gas pressure switch opened 5 times in 24 hours. On the Modulens O AFC-S and the CFU C it is a lockout: the boiler stops and only starts again after our technician has removed the cause and reset it.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
- Can you smell flue gases? Switch the boiler off, open the windows, leave the premises and call us.
Does your boiler show E02.28?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E02.28
The meaning depends on the boiler: find yours below.
The appliance is in Error state because of an extreme value of the flue gas pressure…
Flue gas P error
What our technician checks
- Fouling of the heat exchanger, cleaned
- The burner settings
- Leak-tightness and condition of the flue, cleaned if necessary
- Modulens O AFC-S: the condensate drain and the trap, cleaned
- Modulens O AFC-S: the pressure switch wiring, and the switch replaced if it has failed