Exchanger to flow temperature gap too large
Blocking: it retries by itself
The temperature difference between the heat exchanger and the water leaving for the heating has gone above its maximum, because the water is not flowing enough or because of a sensor (C 230 Evo, AMC, AMC Pro Evo, Virtuens). It is a blocking fault: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, top up with water as the user manual explains.
- Check that the radiator valves are open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.06?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.06
The meaning depends on the boiler: find yours below.
Delta T HEX-T flow max
Maximum difference between the heat exchanger temperature and the…
What our technician checks
- Water circulation: direction, pump and valves
- The system water pressure
- How clean the heat exchanger is
- Whether the system has been bled
- Water quality, against the supplier's specifications
- Operation and fitting of the sensors