De Dietrich Fault code De Dietrich
H.03.02

Flame lost during operation

Blocking: it retries by itself

While the burner is running, the flame goes out: the boiler no longer detects enough ionisation current, the signal that monitors the flame (C 230 Evo, AMC, AMC Pro Evo, MCR-S, MPX2 Compact, Virtuens). It is a blocking fault: the boiler stops and starts again by itself once the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.03.02?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.03.02

The meaning depends on the boiler: find yours below.

H.03.02

Flame loss

Blocking: it retries by itself AMC, AMC Pro Evo, C 230 Evo
H.03.02

Temporary flame loss

Blocking: it retries by itself MCR-S
H.03.02

The measured ionisation current is below the limit

Blocking: it retries by itself Virtuens
H03.02

Temporary loss of flame

Blocking: it retries by itself MPX2 Compact, Virtuens

What our technician checks

  • Purging the gas pipe
  • The gas valve and the gas supply pressure
  • Operation, setting and calibration of the gas valve unit
  • The electrode: connection, wiring and condition
  • The air inlet, the flue and the terminal
  • Flue gas recirculation
  • MPX2 Compact and Virtuens: the supply voltage