Flame lost three times in a row
Breakdown: the boiler is stopped
The burner lost its flame three times during the same heat demand: the oil supply, the flame detection cell or the burner setting is at fault. On the Modulens O AFC-S it is a lockout: the boiler stops, the screen flashes red, and it only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E07.20?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E07.20
The meaning depends on the boiler: find yours below.
3 successive flame losses in the same burner running cycle
What our technician checks
- Tightness of the oil circuit, and whether the oil tap is open
- Condition of the flame detection cell and its alignment with the combustion head sight tube
- Cleanliness of the sight tube mirror
- The burner settings and the recirculation slot
- The nozzle, to be replaced