No water circulation, boiler locked out
Breakdown: the boiler is stopped
The boiler detects no water circulation in its circuit and goes into a permanent fault; possible causes are the pressure or air in the system, the pump, the circulation or a temperature sensor. On the MCR-S, MPX2 Compact and Virtuens it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, water must be added (recommended pressure 1.5 to 2 bar, 1.0 to 2 bar on the MPX2 Compact).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E01.17?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E01.17
The meaning depends on the boiler: find yours below.
No water circulation (permanent)
No water circulation (permanent)
What our technician checks
- The system pressure
- A manual air purge (de-aeration) cycle
- How the pump works
- The water circulation in the boiler and the system
- How the temperature sensors work and are connected