Flame loss or unknown error
Blocking: it retries by itself
On the MCR-S, the burner flame went out for a moment, or the boiler stopped because the mains supply voltage was too low; on the MPX2 Compact and Virtuens, the circuit board reports an unknown error. In both cases it is a temporary stop: the boiler stops and starts again by itself once the cause has gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H03.54?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H03.54
The meaning depends on the boiler: find yours below.
Temporary flame loss
Unknown error
What our technician checks
- The circuit board, replaced if necessary (MPX2 Compact, Virtuens)
- The boiler's power supply and electromagnetic interference on it (MPX2 Compact, Virtuens)
- The electrode: electrical connections and condition (MCR-S)
- The gas inlet pressure and the gas valve calibration (MCR-S)
- The air inlet and the flue terminal (MCR-S)
- The mains supply voltage (MCR-S)