De Dietrich Fault code De Dietrich
H.01.18

No water circulation detected

Blocking: it retries by itself

The boiler detects no water circulation in its circuit; on a Virtuens fitted with the SCB-10 extension board, the same code reports that the flow temperature does not rise after the burner starts. On the MCR-S, MPX2 Compact and Virtuens it is a temporary stop: the boiler stops and starts again by itself once the cause has gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the system water pressure: below 0.8 bar, water must be added (recommended pressure 1.5 to 2 bar, 1.0 to 2 bar on the MPX2 Compact).
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.01.18?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.01.18

The meaning depends on the boiler: find yours below.

H.01.18

No water circulation (temporary)

Blocking: it retries by itself MCR-S
H.01.18

No positive gradient recognised on the flow temperature after burner start

Blocking: it retries by itself Virtuens
H01.18

No water circulation (temporary)

Blocking: it retries by itself MPX2 Compact, Virtuens

What our technician checks

  • The system pressure
  • A manual air purge cycle
  • How the pump works
  • The water circulation in the boiler and the system
  • How the temperature sensors work and are connected

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.