De Dietrich Fault code De Dietrich
E.04.02

Flow temperature sensor disconnected

Breakdown: the boiler is stopped

The sensor that measures the temperature of the water leaving for the heating (the flow) is disconnected or missing, or reads below its range, because of a bad connection or a faulty sensor. On the AMC 24/28 BIC, AMC Pro Evo, C 230 Evo, MCR-S, MPX2 Compact and Virtuens it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E.04.02?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E.04.02

The meaning depends on the boiler: find yours below.

E.04.02

T flow open

Breakdown: the boiler is stopped AMC Pro Evo, C 230 Evo
E.04.02

Flow temp sens open

Breakdown: the boiler is stopped AMC
E.04.02

Flow temperature sensor disconnected

Breakdown: the boiler is stopped MCR-S
E04.02

Flow temperature sensor disconnected

Breakdown: the boiler is stopped MPX2 Compact, Virtuens

What our technician checks

  • The wiring and connectors of the flow sensor
  • How the sensor works
  • The sensor, replaced if it is faulty