De Dietrich Fault code De Dietrich
E07.12

Safety thermostat tripped

Breakdown: the boiler is stopped

The boiler's safety thermostat has tripped, for example because the water is not circulating through the boiler, or because of a bad connection. On the Modulens O AFC-S it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E07.12?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E07.12

The meaning depends on the boiler: find yours below.

E07.12

Safety thermostat tripped

Breakdown: the boiler is stopped Modulens O AFC-S

What our technician checks

  • Bleeding the air from the heating system
  • Water circulation: direction, pump and valves
  • The water pressure
  • How clean the heat exchanger is
  • The wiring between the CU-OH-02 board and the thermostat
  • How the thermostat is fitted, replaced if necessary