Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
De Dietrich Fault code De Dietrich
H02.27

Flue gas temperature too high

Blocking: it retries by itself

The flue gas temperature has reached an extreme value, for example because the heat exchanger is fouled. On the Modulens O AFC-S and the CFU C it is a blocking fault: the boiler starts again by itself once the cause is gone, but if the code appears 5 times in 24 hours it locks out (code E02.29).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.
  3. Can you smell flue gases? Switch the boiler off, open the windows, leave the premises and call us.

Does your boiler show H02.27?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H02.27

The meaning depends on the boiler: find yours below.

H02.27

The appliance is in Block state because of an extreme value of the flue gas temperature…

Blocking: it retries by itself Modulens O AFC-S
H02.27

Flue gas T block

Blocking: it retries by itself CFU C

What our technician checks

  • Modulens O AFC-S: the wiring
  • Fouling of the heat exchanger, cleaned if necessary
  • The burner settings and the combustion measurements

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.