False flame detected
Breakdown: the boiler is stopped
The boiler sees a flame signal when there should be none, for example before the burner starts: a burner that keeps glowing, the electrode, the gas valve, the ignition transformer, the earthing or the supply voltage may be the cause. On the AMC 24/28 BIC, AMC Pro Evo, C 230 Evo, MCR-S, MPX2 Compact and Virtuens it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E.04.12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E.04.12
The meaning depends on the boiler: find yours below.
Parasitic flame
False flame
Ignition failure for false flame detection
Ignition failure for false flame detection
What our technician checks
- The O2 setting if the burner keeps glowing
- The ignition and ionisation electrode, and its condition
- The gas valve, replaced if it is faulty
- The ignition transformer, replaced if it is faulty
- The earthing circuit
- The mains supply voltage