SMI closed position not detected
Breakdown: the boiler is stopped
On the Gas 210 Eco, the boiler does not detect the closed position of the flag of its air/gas mixing system (SMI): dirty light sensor, badly set flag, wiring or SMI circuit board at fault. The boiler goes into lockout (the digits flash) and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 87?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 87
The meaning depends on the boiler: find yours below.
Closed position of the SMI flag not detected
What our technician checks
- Whether the light sensor is clean
- The setting of the SMI 0 % flag
- The SMI wiring and connectors
- The SMI circuit board, replaced if everything else is in order