Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
E00.16

Hot water tank sensor open or missing

Breakdown: the boiler is stopped

The sensor that measures the temperature of the domestic hot water tank is not connected, open or reads below its measuring range: a bad connection or a faulty sensor. On the Calenta Ace, Tzerra Ace, Quinta Ace, Quinta 45-115, Calenta Ace-Matic, Tzerra Ace-Matic and Avanta Ace it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E00.16?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E00.16

The meaning depends on the boiler: find yours below.

E.00.16

DHW cylinder temperature sensor not connected

Breakdown: the boiler is stopped Avanta Ace
E.00.16

DHW T open

Breakdown: the boiler is stopped Quinta 45-115
E00.16

Domestic hot water cylinder temperature sensor not connected

Breakdown: the boiler is stopped Calenta Ace-Matic, Tzerra Ace-Matic
E00.16

Cylinder T open

Breakdown: the boiler is stopped Calenta Ace
E00.16

The domestic hot water cylinder sensor is missing or the measurement is below the range

Breakdown: the boiler is stopped Tzerra Ace
E00.16

DHW sensor discon.

Breakdown: the boiler is stopped Quinta Ace

What our technician checks

  • The tank sensor's wiring and connectors, up to the circuit board
  • The sensor's operation and its resistance
  • The sensor, replaced if faulty
  • If the tank has been removed: the DP150 setting

Related codes