The burner fails to light
Breakdown: the boiler is stopped
The boiler tried several times to light its burner and failed: five attempts on most models, four on the Avanta Ace. The boiler locks out for safety and stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E04.10?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E04.10
The meaning depends on the boiler: find yours below.
The burner failed to ignite after 4 attempts
Ignition failure
The burner failed to ignite after five attempts.
Ignition error
5 ignitions have failed
Ignition failure
What our technician checks
- The gas tap, the gas supply pressure and purging the gas line
- The gas valve: connection, wiring, calibration and setting
- The ignition and ionisation electrode: condition, connection and cable
- The ignition transformer wiring and the earthing
- The condition of the burner deck
- The air supply and flue gas ducts (blockage)
- Fan operation
- The circuit board, replaced if necessary