Flame lost during operation
Breakdown: the boiler is stopped
The boiler lost the signal of its flame (ionisation) during operation, 4 restarts in a row within one heat demand: the manuals name flue gases coming back into the combustion air, too little air because of a blockage, or badly adjusted combustion. The boiler goes into lockout (the digits flash): do not reset it, our technician must first check the ducts and the combustion.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
Does your boiler show 77?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 77
The meaning depends on the boiler: find yours below.
Ionisation fault during operation
Lack of ionisation during operation (after 4 new start attempts during one heat demand)
Loss of ionisation during operation (after 4restarts during 1 heat demand)
The boilers that show this code
What our technician checks
- Flue gas recirculation: tightness of the heat exchanger, fitting of the flue system and terminal
- The fan and whether the air and flue ducts are clear
- The combustion setting (CO2 / O2)
- Quinta 115: the gas supply (blockage, pressure regulator, gas pressure too low)