Safety input open or overheating
Breakdown: the boiler is stopped
A safety device has shut the boiler down: on the Quinta 45-115, Tzerra Ace and Gas 210, 220 and 320/620 Ace the safety input has opened because the differential air pressure switch tripped, for example on too high a pressure in the flue; on the Avanta Ace the maximum safety temperature has been reached. The boiler locks out and stays off: the cause must be found before it is put back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
Does your boiler show E04.08?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E04.08
The meaning depends on the boiler: find yours below.
Maximum safety temperature value reached
Safety input
The safety input is open
What our technician checks
- The wiring and connectors of the differential air pressure switch
- The air supply and flue gas ducts (blockage)
- The condensate trap, blocked or empty
- The non-return valve, which must open
- How clean the heat exchanger is
- Avanta Ace: water pressure, venting, pump and circulation
- Avanta Ace: connection and operation of the safety thermostat