Remeha Fault code Remeha
E44

Parameter check failed

Breakdown: the boiler is stopped

The check of the control's parameters (checksum) has found a wrong setting. On the Avanta, Avanta Plus, Avanta Platinum Plus and Aquanta the boiler locks out: it only restarts once our technician has corrected the parameters and the reset button is pressed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E44?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E44

The meaning depends on the boiler: find yours below.

E44

Parameter checks

Breakdown: the boiler is stopped Avanta Platinum Plus, Avanta Plus
E44

Parameter checksum

Breakdown: the boiler is stopped Aquanta, Avanta

What our technician checks

  • The parameter settings, to be corrected (Avanta Plus)
  • Return to factory settings (Avanta Platinum Plus)
  • The dF and dU codes, to be reprogrammed (Avanta, Aquanta)
  • Restoring with the Recom software, otherwise replacing the control unit (Avanta, Aquanta)