9
Control stop, flow temperature too high
Information: nothing to do
On the Quinta, while heating hot water, the water leaving the boiler is 5 °C above the calculated temperature and the burner stops for a while: this is the normal control stop in hot water mode. On the W40/60-m Eco this operating code stops the burner when the flow temperature goes above 95 °C or 5 °C above its setpoint, when the difference with the return goes above 45 °C or when the flow temperature rises too fast.
The variants of code 9
The meaning depends on the boiler: find yours below.
9
Flow temperature exceeds the calculated set point by 5°C (normal stop in DHW mode)
Information: nothing to do
Quinta 25/30s 28/35c, Quinta 45/65
9
Flow temperature > calculated set point (DHW) + 5°C
Information: nothing to do
Quinta 115, Quinta 85
9
Flow temperature > 95°C / Maximum flow temperature exceeds the programmed value by 5K
Information: nothing to do
W40/60-m Eco