Flame lost during operation
Blocking: it retries by itself
While the burner is running, the flame goes out: the ionisation current that monitors it drops below its limit (Calenta Ace and Ace-Matic, Tzerra Ace and Ace-Matic, Avanta Ace, Quinta Ace and Quinta 45-115, Gas 210, 220 and 320/620 Ace). It is a blocking message: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H03.02?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H03.02
The meaning depends on the boiler: find yours below.
Temporary flame loss
Flame loss
Temporary loss of flame
Flame loss
Flame loss detected
What our technician checks
- Bleeding the gas pipe
- The gas tap, fully open, and the gas supply pressure
- Operation, setting and calibration of the gas valve
- The electrodes: their condition and electrical connections (Calenta and Tzerra Ace-Matic, Avanta Ace)
- The air supply and the flue: clear ducts, terminal
- No flue gas recirculation
- The supply voltage (Calenta and Tzerra Ace-Matic)