Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
H02.04

Error in the circuit board settings

Blocking: it retries by itself

The circuit board cannot read its settings (Calenta Ace-Matic, Tzerra Ace-Matic, Avanta Ace) or finds them wrong, with incorrect factory settings (Calenta Ace, Tzerra Ace, Quinta Ace, Quinta 45-115, Gas 210, 220 and 320/620 Ace). It is a blocking message: the boiler stays off and starts again by itself once our technician has put the settings right.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H02.04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H02.04

The meaning depends on the boiler: find yours below.

H.02.04

The PCB parameters cannot be read.

Blocking: it retries by itself Avanta Ace
H.02.04

Parameter error

Blocking: it retries by itself Gas 210 Ace, Gas 220 Ace, Gas 320/620 Ace, Quinta 45-115
H02.04

Unable to read the parameters from the PCB

Blocking: it retries by itself Calenta Ace-Matic, Tzerra Ace-Matic
H02.04

Parameter error

Blocking: it retries by itself Calenta Ace, Quinta Ace, Tzerra Ace

What our technician checks

  • A restart of the boiler
  • The CN1 and CN2 settings, entered again
  • The external configuration memory (CSU), replaced if needed (Calenta and Tzerra Ace-Matic)
  • The circuit board, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.