False flame detected by the boiler
Breakdown: the boiler is stopped
The boiler detects a flame signal at a moment when there should be none, for example before the burner starts. The boiler locks out for safety and stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E04.12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E04.12
The meaning depends on the boiler: find yours below.
Ignition failed due to false flame detection
False flame
Ignition failed due to false flame detection
False flame
False flame detected
What our technician checks
- The earthing circuit
- The mains supply voltage
- The ignition and ionisation electrode
- A burner that keeps glowing: the O2 setting
- The gas valve, replaced if faulty
- The ignition transformer, replaced if faulty