Fault codes Buderus

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

The code is sometimes followed by a number (6A 227): the code is enough.

Your brand

Your boiler Buderus

The model is written on the rating plate, often under the cover.

All codes Buderus

-A Chimney sweep mode or service mode
-H Boiler in heating mode
0A Waiting before the burner restarts
0C Burner start-up in progress
0E Heat demand below the minimum output
0H Boiler ready, no heat demand
0L Gas valve opening at start-up
0U Boiler starting up
0Y Heating water hotter than expected
1A Flue gas temperature too high
1C Flue gas temperature too high
1P Flue gas temperature rising very fast
1U Flue gas temperature sensor short-circuited
1Y Flue gas temperature sensor fault
240-259 Burner control unit or HCM module faulty
242-263 Electronics or basic controller fault
2914-2916 System fault in the electronics
2923-2926 Boiler electronics fault
2923-2927 System fault related to the gas valve
2A Abnormal temperature rise
2C Water too hot during hot water production
2E Water pressure too low (or venting in progress)
2F Water temperature not rising as expected
2H Anti-seize protection for pump and 3-way valve
2L No water circulation detected
2P Temperature rising too fast
2U Abnormal water circulation in the boiler
2Y Heating pump problem
3A Fan stopped during operation
3C Problem with the fan
3F Safety check after 24 hours of operation
3H Air temperature too high
3L Fan not running at startup
3P Fan running too slowly
3U Air and flue gas sensors incorrectly positioned
3Y Fan running too fast
4A Heating water too hot
4C Temperature too high: safety device tripped
4E Temperature sensor test failed
4F Water too hot at the safety sensor
4L Safety sensor short-circuited or water above 130 °C
4P Safety temperature sensor open circuit
4U Flow temperature sensor short-circuited
4Y Flow temperature sensor open circuit
5A Boiler operating message
5C Diagnostic tool connected
5F Service test running too long
5H Boiler in test mode
5L No communication with the burner control
5P Too many resets
5U Communication problem with the UM10 module
5Y UM10 module silent, or service test too long
6A No flame at ignition
6C Flame detected while the burner is off
6L Flame goes out during operation
6P Ignition activated for too long
6U No flame at ignition (oil)
6Y Flame detected during pre-purge
7A Supply voltage too low or interrupted
7C Power supply interrupted
7H Power interruption or voltage drop
7L Burner electronics timing error
7P Safety chain open
8C Boiler blocked after repeated faults
8U No feedback from the UM10 module
8Y Boiler blocked by an external contact
9A Incorrect coding plug (KIM)
9H Burner control unit or coding plug (KIM) faulty
9L Fault in the gas valve or its control
9P KIM not recognized or burner control unit faulty
9U Coding plug (KIM) or burner control unit fault
9Y Internal fault in the burner control
=H Boiler in hot water mode
A01 Sensor, hot water or hydraulic setting fault
A11 Controller: configuration, link or sensor fault
A21 Circuit 1 remote control not connected
A22 Circuit 2 remote control not connected
A23 Circuit 3 remote control not connected
A24 Circuit 4 remote control not connected
A31 Circuit 1 flow sensor faulty
A32 Circuit 2 flow sensor faulty
A33 Circuit 3 flow sensor faulty
A34 Circuit 4 flow sensor faulty
A41 Hot water thermal disinfection failed
A51 Solar collector or cylinder sensor faulty
A61 Circuit 1: outdoor sensor or two master controllers
A62 Circuit 2: outdoor sensor or two master controllers
A63 Circuit 3: outdoor sensor or two master controllers
A64 Circuit 4: outdoor sensor or two master controllers
A8 BUS communication interrupted
AD1 Boiler stays cold
C0 Water pressure sensor fault
CA Return water too hot
CU Return temperature sensor short-circuited
CY Temperature sensor: impossible value
E1 Burner control unit or KIM faulty
EA Burner control unit or coding plug faulty
EC Burner control unit or coding plug (KIM) faulty
EE Internal burner control unit fault
EF Burner control unit or KIM faulty
EH Burner control unit or coding plug fault
EL Control electronics fault
EP Burner control unit or coding plug faulty
EU UM10 switching module fault
EY Burner control unit or coding plug (KIM) faulty
H01 Heat pump alarm
H03 Service due: operating hours reached
H06 Flame often lost at startup
H07 Water pressure too low
H08 Boiler service due
H11 DHW sensor faulty (GB162 T10, T40 S)
H12 Hot water cylinder sensor faulty
LL Too many restarts despite unlocking
LP Too many resets
200 Boiler in heating mode
201 Domestic hot water heating in progress
202 Pause between two burner starts
203 Boiler ready, no heat demand
204 Waiting: the water is already hot enough
207 Water pressure too low
208 Chimney sweep mode (flue gas test)
210 Flue gas temperature too high
212 Temperature rising too fast
213 The temperature is rising too fast
214 Fan stopped during ignition
215 Fan running too fast
216 Fan running too slowly
217 Fan running irregularly at start-up
218 Heating water too hot (over 105 °C)
219 Water too hot at the safety sensor
220 Safety sensor short-circuited or water above 130 °C
221 Safety temperature sensor circuit open
222 Flow temperature sensor short-circuited
224 Safety temperature limiter tripped
227 No flame after ignition
228 Flame signal without a flame
229 Flame lost during operation
231 Power outage during a fault
232 Boiler blocked by an external contact
233 Identification module not recognized
234 Gas valve electrical fault
235 Electronics and identification module incompatible
237 Electronics system fault
238 Boiler electronics faulty
239 Burner control unit or coding plug faulty
260 No temperature rise after ignition
261 Burner control unit faulty
262 Burner control unit or HCM module faulty
263 Faulty burner control box or coding module
264 Fan has failed
265 Heat demand below minimum output
268 Boiler in test mode
269 Ignition active for too long
270 Boiler starting up
272 Faulty burner control box or coding module
273 Check shutdown after 24 hours of operation
276 Heating water too hot (over 95 °C)
280 Faulty burner control box
281 Heating pump blocked or air-locked
282 No feedback signal from the pump
283 Burner starting up
284 Burner start-up: gas valve opens
290 Faulty burner control box or coding module
305 Waiting time after hot water production
306 Flame detected after gas shutoff
307 Heating pump not running
316 Flue gas too hot during sensor test
317 Flue gas temperature sensor short-circuited
318 Flue gas temperature sensor open circuit
323 BUS communication interrupted
328 Brief power interruption
330 Faulty external flow temperature sensor
331 Faulty external flow temperature sensor (hydraulic separator)
341 Temperature rising too fast
342 Temperature rising too fast
349 Flow and return difference too large
350 Flow temperature sensor short-circuited
351 Flow temperature sensor open circuit
356 Power supply voltage too low
357 Venting program running
358 Pump anti-seize protection
360 Basic controller system fault
361 Electronics and coding module mismatch
362 Boiler identification module fault
363 Electronics system fault
364 Gas valve not closing properly
365 Gas valve not closing properly
390 Incorrect value in the coding module
701 Low pressure fault in the refrigerant circuit
702 Low pressure: stop and automatic restart
703 Frost protection: flow below 5 °C
704 Refrigerant circuit temperature too high
705 Fan motor protection tripped
707 Heat pump coding fault
708 Return temperature sensor fault
709 Flow temperature sensor fault
710 Refrigerant circuit sensor fault
711 Outdoor temperature sensor fault
712 Domestic hot water sensor fault
713 Heat source inlet sensor fault
714 Hot water blocked: thermal limit exceeded
715 High pressure: stop and automatic restart
716 High pressure fault in the refrigerant circuit
718 Outdoor temperature above the allowed limit
719 Outdoor temperature below the allowed limit
722 Negative temperature difference in heating mode
723 Negative temperature difference in hot water mode
724 Temperature difference too small during defrost
725 Domestic hot water production fault
726 Mixing circuit 1 sensor fault
727 Low pressure in the brine circuit
728 Heat source outlet sensor fault
729 Phase sequence error: compressor without power
730 Screed drying: not enough power
733 Hot water tank anode fault
734 Anode fault for two weeks: hot water blocked
735 External backup heater sensor fault
736 Solar collector sensor fault
737 Solar hot water tank sensor fault
738 Mixing circuit 2 sensor fault
750 External return sensor fault
751 Phase monitoring relay tripped
752 Phase sequence or flow fault
755 Connection lost with a slave heat pump
756 Connection lost with the master heat pump
758 Defrost interrupted: not enough heat
760 Defrost ended by its maximum time
811 Thermal disinfection of hot water failed
815 Hydraulic separator sensor faulty
1000 System configuration not confirmed
1010 No communication with the controller (EMS bus)
1011 Flue gas temperature too high
1012 Fan running irregularly
1013 Service due: burner hours reached
1017 Water pressure too low
1018 Service due: date reached
1019 Wrong pump type detected
1021 Domestic hot water sensor faulty
1022 Hot water cylinder sensor faulty
1023 Service due: interval reached
1025 Return temperature sensor faulty
1037 Outdoor temperature sensor faulty
1038 Invalid date or time
1039 Screed drying not possible on this circuit
1040 Screed drying: only with the whole system
1041 Power outage during screed drying
1042 Internal clock fault
1065 Water pressure sensor faulty or disconnected
1068 Outdoor temperature sensor faulty
1070 Boiler service to schedule
1071 Boiler service due now
1072 Service date has passed
1074 No signal from the flow temperature sensor
1075 Heat exchanger sensor short-circuited
1076 No signal from the heat exchanger sensor
2085 Internal boiler fault
2908 System fault in the electronics
2910 Flue gas exhaust fault
2920 Flame monitoring fault
2927 No flame detected at ignition
2928 Internal boiler fault
2931 Electronics or basic controller fault
2940 Burner control unit system fault
2946 Wrong coding plug
2948 No flame signal at low output
2949 No flame signal at high output
2950 No flame after start-up
2951 Flame lost too often
2952 Internal fault during flame signal test
2955 Hydraulic setting not supported
2956 Hydraulic configuration activated
2957 System fault in the electronics
2963 Temperature sensor signal out of range
2964 Water flow too low in the boiler
2965 Flow temperature too high
2966 Flow temperature rising too fast
2967 Temperature difference too large between two sensors
2968 Heating water top-up in progress
2969 Maximum number of refills reached
2970 Water pressure dropping too fast
2971 Water pressure too low
2972 Power supply voltage too low
2980 Boiler locked out after too many faults
2981 Safety lockout: boiler turned off and on
2982 No water flow or flow too low
3071 No communication with the remote control
3091 Room temperature sensor faulty
4052 Hot water thermal disinfection failed
5111 TC3 sensor signal out of range
5143 Flow and return swapped between the units
5203 Outdoor temperature sensor T1 fault
5206 Flow temperature sensor T0 fault
5239 Hot water sensor TW1 fault
5378 Outdoor unit defrost fault
5485 Too little flow to the heat pump
5522 Indoor unit and heat pump do not match
5594 Air in the system
6242 Backup heater overheat protection tripped
6243 High flow and return temperature difference
6248 Underfloor heating limiter tripped
6253 Electric backup heater too hot