No water circulation detected
Blocking: it retries by itself
The boiler's pressure sensor measures neither a pressure rise nor any flow: the heating water is not circulating enough. This is a blocking fault: the boiler tries to clear the fault by itself and restarts as soon as the cause is gone.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check the water pressure: at least 1 bar, or the needle in the green zone of the pressure gauge. Too low? Top up with the boiler cold, the way your installer showed you.
- Check that enough radiators are open.
- Bleed the radiators.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 2L?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 2L
The small number shown beside the code tells which.
The pressure sensor does not measure any flow
The sensor does not measure any pressure rise
The boilers that show this code
What our technician checks
- The water pressure, and venting of the system and the boiler
- The water flow rate in the system
- The wiring of the pump and the pressure sensor, replaced if necessary
- The operation of the pressure sensor