Heating water too hot
Breakdown: the boiler is stopped
The water in the boiler has exceeded the maximum permitted temperature and the boiler has shut down for safety. Most often, the water is not circulating well: lack of water, air in the system, the pump or a valve.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check the water pressure: at least 1 bar, or the needle in the green zone of the pressure gauge. Too low? Top up with the boiler cold, the way your installer showed you.
- Check that enough radiators are open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 4A?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 4A
The small number shown beside the code tells which.
The temperature measured by the flow temperature sensor is higher than 105 °C
The temperature measured by the flow temperature sensor is higher than 110 °C
Flow temperature above maximum permitted value
The boiler flow temperature exceeds the maximum permitted value
The boilers that show this code
What our technician checks
- The water pressure and bleeding of the system
- The circulation: water flow rate, pump, check valves and anti-thermosiphon valves
- The flow temperature sensor
- The hydraulic circuit