Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
4U

Flow temperature sensor short-circuited

Breakdown: the boiler is stopped

The sensor that measures the heating water temperature is sending an impossible signal. The boiler no longer knows what temperature it is heating to and shuts down as a precaution.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 4U?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 4U

The small number shown beside the code tells which.

4U
222

Flow temperature sensor faulty (short circuit)

Breakdown: the boiler is stopped GB072, GB162, GB172, GB172i
4U
350

Flow temperature sensor faulty (short circuit)

Blocking: it retries by itself GB072, GB162, GB172, GB172i
4U
521

Too large a difference between boiler flow temp. of sensors 1 and 2

Breakdown: the boiler is stopped GB212, KB192i, KB192i.2, KB195i, KB195i.2
4U
522

Short circuit between boiler flow temperature sensors 1 and 2

Breakdown: the boiler is stopped GB212, KB192i, KB192i.2, KB195i, KB195i.2
4U
524

Boiler flow temperature sensor short circuit

Breakdown: the boiler is stopped GB212, KB192i, KB192i.2, KB195i, KB195i.2

The boilers that show this code

What our technician checks

  • The flow sensor and its cable (short circuit)
  • The connectors of the sensor and the burner control unit (dirt)
  • The sensor values, measured with an ohmmeter and compared with the manufacturer's table
  • The flow and return connections
  • The sensor or the burner control unit, replaced if necessary

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.