Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
2E

Water pressure too low (or venting in progress)

Blocking: it retries by itself

On the GB162 and the KB192i, KB192i.2 and GB212 floor-standing boilers, the system water pressure is too low. On the GB072, GB172 and GB172i, the same code only means that the venting function is active, which is not a fault.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Check the water pressure: at least 1 bar, or the needle in the green zone of the pressure gauge. Too low? Top up with the boiler cold, the way your installer showed you.
  3. Do you often have to add water? Let us know: there is probably a leak or a faulty expansion vessel.
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 2E?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 2E

The small number shown beside the code tells which.

2E
207

Operating pressure too low

Blocking: it retries by itself GB162, GB212, KB192i, KB192i.2
2E
357

Venting function active

Information: nothing to do GB072, GB172, GB172i

The boilers that show this code

What our technician checks

  • Filling the system to 2 bar, and venting it
  • Leaks in the system, repaired before filling
  • The expansion vessel
  • The pressure sensor and its wiring, sensor replaced if necessary

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

Related codes