Flame goes out during operation
Breakdown: the boiler is stopped
While the burner is running, the boiler loses the flame signal. It tries to restart by itself; if the flame is lost too often, it locks out for safety.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 6L?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 6L
The small number shown beside the code tells which.
No ionisation signal during burner operation
Flame loss during the post-ignition time
Flame failure during the stabilisation time
Flame failure during 1st + 2nd stage operation
Flame loss when switching to 1st stage
Flame loss during 1st-stage operation
Flame loss when switching to 1st and 2nd stage
Too many restarts
Too many flame losses
Flame failure during ignition gas stabilisation
Voltage interrupted during burner start
Flame failure during part-load stabilisation
Flame loss during 1st and 2nd stage operation
Flame loss when switching to 1st stage
Flame loss during the change-over to 1st + 2nd stage
Flame loss during the safety time
Flame loss during the safety time
Flame loss during 1st-stage operation
Too many burner start attempts
The boilers that show this code
What our technician checks
- The gas supply (dynamic pressure, tightness) or the oil supply
- The monitoring electrode: wiring, connector, dirt and position
- The flame current, read on the control module
- The ignition (relay test) and the ignition device: wear, damage, electrode gap
- The burner setting, according to its settings table
- The air supply and the flue (blockage), and the pressure switch
- The blocking fault memory, to see when the flame is lost
- The connection of the first-stage and second-stage solenoid valves
- Oil boilers: the flame sensor, the nozzle, the preheater shutoff valve and the mixing system
- Dirt buildup in the boiler and, on room-sealed units, the tightness of the flue (CO or CO2 in the fresh air)
- The power supply, if the burner control unit was switched off several times at startup