Flame lost during operation
Blocking: it retries by itself
The burner flame went out while the boiler was heating. This is not a lockout: the boiler restarts by itself as soon as the cause is gone.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that the boiler's gas shutoff valve is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 229?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 229
The small number shown beside the code tells which.
Flame failure during burner operation
The boilers that show this code
What our technician checks
- The gas shutoff valves (main and appliance) and the gas line
- The dynamic gas pressure
- The monitoring electrode, its cable and connector, the ignition cable and the igniter (wear, damage)
- Grounding (PE) in the control unit
- The burner adjustment, also at minimum load, and its nozzles
- The flue gas outlet and the combustion air supply (ventilation opening)
- The heat exchanger on the flue gas side, cleaned
- The gas valve, the circuit board and the control unit, replaced if needed