Boiler blocked by an external contact
Blocking: it retries by itself
An external contact connected to the boiler is open and is blocking the burner: depending on the model, an external thermostat or temperature limiter, a failed condensate pump, an external blocking terminal or a solid fuel boiler in operation. This is a blocking fault: the boiler restarts by itself as soon as the contact closes again.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 8Y?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 8Y
The small number shown beside the code tells which.
The AT90 temperature controller has tripped / AT90 temperature controller faulty / The jumper on the connection terminals for the…
External lock via connection terminal EV 1,2
External lock of the switching module
The boilers that show this code
What our technician checks
- The external switch contact, and the jumper across its terminals if no contact is connected
- The setting of the external thermostat (AT90, TB 1) and of the heating controls
- The sensor of this thermostat and its cable (open circuit, short circuit), replaced if necessary
- The external temperature limiter, to be reset
- The condensate drain and the condensate pump, replaced if necessary
- The cable and the external blocking terminal EV 1,2 (KB195i, KB195i.2)
- The voltage at the external contact of the UM10 module (KB195i)