Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
9L

Fault in the gas valve or its control

Breakdown: the boiler is stopped

The boiler detects a fault in the gas valve (coil, cable or contacts) or in the electronics that control it. For safety, the boiler locks out and will only restart after a reset.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 9L?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 9L

The small number shown beside the code tells which.

9L
230

Gas valve faulty

Breakdown: the boiler is stopped GB172i
9L
234

Gas valve coil or connecting cable faulty

Breakdown: the boiler is stopped GB072, GB162, GB172, GB172i
9L
238

Gas line faulty

Breakdown: the boiler is stopped GB072, GB162, GB172, GB172i

The boilers that show this code

What our technician checks

  • The wiring and connector of the gas valve, replaced if necessary
  • The gas valve, replaced if necessary
  • The wiring and connectors of the burner control unit, and the burner control unit or the control unit, replaced if necessary

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.