Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
306

Flame detected after gas shutoff

Breakdown: the boiler is stopped

After the burner stops, the boiler still sees a flame signal: the gas may not be shutting off properly. It locks out for safety.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 306?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 306

The small number shown beside the code tells which.

306

Flame signal after the fuel supply has been closed

Breakdown: the boiler is stopped GB172i.2, GB182i.2, GB192i, GB192i.2, GB272

The boilers that show this code

What our technician checks

  • The ionization cable and element, and the ignition device
  • The cleanliness of the heat exchanger around the ignition
  • The gas-air ratio after shutdown
  • The gas valve closing at shutdown, valve replaced if necessary
  • The burner control unit, replaced if necessary

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

6C

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.