Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
5Y

UM10 module silent, or service test too long

Breakdown: the boiler is stopped

On KB192i and KB195i floor-standing boilers, the UM10 switching module communicates but no longer gives a signal. On the GB162, a service test with the diagnostic tool took too long, or a boiler parameter has changed.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 5Y?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 5Y

The small number shown beside the code tells which.

5Y

Diagnostic plug (service tool): the service test is taking too long or a boiler…

Blocking: it retries by itself GB162
5Y
585

Switching module missing

Breakdown: the boiler is stopped KB192i, KB195i

The boilers that show this code

What our technician checks

  • The UM10 module: never to be removed, replaced if necessary (KB195i)
  • A removed UM10: to be uninstalled in the software as well (KB192i)
  • A restart of the boiler (reset) after the service test (GB162)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.