Buderus Fault code Buderus
4052

Hot water thermal disinfection failed

Blocking: it retries by itself

On a Logatherm WLW176i or WLW186i heat pump (BC400 control), the thermal disinfection of the hot water cylinder did not complete. Possible causes: hot water drawn continuously or a leak, a badly placed hot water sensor, or an electric backup heater too weak for the water volume.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 4052?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 4052

The meaning depends on the boiler: find yours below.

4052

Thermal disinfection failed

Blocking: it retries by itself BC400

What our technician checks

  • A constant hot water draw or a leak
  • The position and fixing of the hot water sensor
  • The cylinder heating coil
  • The pipes between the heat pump and the cylinder, and their connections
  • The hot water circulation pipe and its pump
  • The hot water sensor, checked against the table, replaced if it differs
  • The system configuration and the maximum disinfection time (0 to 180 min)