Safety chain open
Blocking: it retries by itself
A safety device connected to the boiler has tripped, for example the minimum pressure switch when the water pressure is too low, or the overflow safety device of the condensate neutralizer. This is not a lockout: the boiler restarts by itself as soon as the cause has cleared.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check the water pressure: at least 1 bar, or the needle in the green zone of the pressure gauge. Too low? Top up with the boiler cold, the way your installer showed you.
- Do you often have to add water? Let us know: there is probably a leak or a faulty expansion vessel.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 7P?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 7P
The small number shown beside the code tells which.
Safety chain open
The boilers that show this code
What our technician checks
- The flue gas path, the siphon and the condensate neutralizer (clogging)
- The flue gas or combustion chamber pressure switch, reset if necessary
- The air intake and flue gas outlet openings, and their ducts (blockage)
- The safety device and the continuity of the chain components, replaced if necessary
- The operating pressure of the heating circuit (KB195i.2)