Temperature rising too fast
Blocking: it retries by itself
The water temperature in the boiler is rising too fast. The boiler protects itself: the cause is too little heat being drawn off (closed thermostatic valves), too low a water flow, or the pump.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that enough radiators are open.
- Bleed the radiators, then check the water pressure again.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 2P?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 2P
The small number shown beside the code tells which.
The flow and safety temperature sensors measure a temperature rise that is too fast
Gradient limitation: temperature rising too fast in heating mode
Gradient limitation: temperature rising too fast in DHW mode
Flow temperature rising too fast
The boilers that show this code
What our technician checks
- The water pressure, and venting of the system and the boiler
- The water flow in the system, isolation valves open
- The pump: connection, start-up, output or pump curve setting; replaced if necessary
- The temperature sensor concerned and its wiring
- Heat dissipation through the system
- Floor-standing boilers: water-side deposits in the heat exchanger, flushed out with a product suitable for aluminum