Hot water thermal disinfection failed
Blocking: it retries by itself
On a Logatherm or Bosch Compress heat pump (HMC300, HMC310 or HPC410 control), the thermal disinfection of the hot water cylinder did not complete (number shown next to it: 4051 or 4052). The system keeps running as far as possible; possible causes are a constant hot water draw or a leak, a badly placed hot water sensor, or an electric backup heater too weak for the water volume.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show A41?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code A41
The small number shown beside the code tells which.
Domestic hot water production: thermal disinfection failed
What our technician checks
- A constant hot water draw or a leak
- The position and fixing of the hot water sensor
- Hot water priority, if heating and hot water run in parallel
- Venting the cylinder coil
- The pipes between the unit and the cylinder, and their connections
- The output of the built-in hot water charging pump
- Losses in the circulation pipe
- The hot water sensor, checked against the table, and the maximum hot water time (60 to 240 min)