Sensor, hot water or hydraulic setting fault
Breakdown: the boiler is stopped
The boiler reports a fault: faulty outdoor sensor or hot water sensor, hot water that stays cold, or an unsupported hydraulic configuration. The number shown next to the code (800, 808, 810 or 845) tells which one; this is a locking fault.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show A01?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code A01
The small number shown beside the code tells which.
The outdoor temperature sensor is faulty
DHW temp. sensor 1 faulty. Deactivate the DHW function if necessary.
The domestic hot water stays cold
The hydraulic configuration is not supported
The boilers that show this code
What our technician checks
- The connection, cable and mounting of the sensor (outdoor or cylinder)
- The sensor resistance, compared with its characteristic curve
- A leak or constant hot water draw, and the cylinder charging pump
- The configuration of the hot water, heating circuit 1 and the system pump on the module