No flame after ignition
Breakdown: the boiler is stopped
On recent boilers, the same problem as 6A: ignition has taken place, but no flame is detected. The boiler shuts down for safety.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that the boiler's gas shutoff valve is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 227?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 227
The small number shown beside the code tells which.
No flame signal after ignition
The boilers that show this code
What our technician checks
- The gas shutoff valves (main and appliance)
- The gas line and the gas pressure
- The burner adjustment: CO2 content and air/gas ratio
- Grounding, ignition and ionization current
- The electrodes, their cables and connectors
- The condensate drain and fouling of the heat exchanger on the flue gas side
- The gas valve and the burner control unit, replaced if needed