213
The temperature is rising too fast
Information: nothing to do
The flow or return temperature sensors measure a temperature rise that is too fast. To check: the pressure and venting, the water circulation and an output suited to the system.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that enough radiators are open.
- Bleed the radiators, then check the water pressure again.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Nothing to do
This message belongs to the boiler's normal operation.
Call usChoose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 213
The small number shown beside the code tells which.
213
The flow or return temperature sensor measures a temperature rise that is too fast
Information: nothing to do
GB192i
The boilers that show this code
What our technician checks
- The water pressure, and venting of the boiler and the system
- The water flow rate in the system
- The boiler output, set according to the size of the system
- The wiring of the pump and the sensor involved; replaced if needed