Buderus Fault code Buderus
2U

Abnormal water circulation in the boiler

Breakdown: the boiler is stopped

The boiler measures a temperature rise that is too fast, or too large a difference between flow and return; on floor-standing boilers, it can also detect water flowing in the wrong direction. Depending on the case, it starts again by itself once the problem is gone, or locks out.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Check that enough radiators are open.
  3. Bleed the radiators, then check the water pressure again.
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 2U?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 2U

The small number shown beside the code tells which.

2U
213

The flow or safety temperature sensor measures a temperature rise that is too fast

Blocking: it retries by itself GB162
2U
349

The temperature difference measured at low load between the flow temperature sensor and…

Blocking: it retries by itself GB162
2U
533

The heat source has detected an incorrect water-side flow

Breakdown: the boiler is stopped GB212, KB192i
2U
565

Flow and return temperature difference too large

Blocking: it retries by itself GB212, KB192i

The boilers that show this code

What our technician checks

  • The operating pressure and venting of the system and the boiler
  • The water flow rate in the system
  • The heating output, set to match the size of the system
  • The wiring of the pump and the sensor concerned, replaced if necessary
  • Floor-standing boilers: flow and return not swapped, and correct flow direction of the pumps
  • Floor-standing boilers: the system configuration, since the flow-return difference can also occur in normal operation

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.