Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
EH

Burner control unit or coding plug fault

Breakdown: the boiler is stopped

The burner control unit, the control unit or the identification module (KIM, coding plug) is faulty. The boiler locks out and will only restart after a reset.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show EH?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code EH

The small number shown beside the code tells which.

EH
250

The burner control unit or the KIM is faulty

Breakdown: the boiler is stopped GB162
EH
258

The burner control unit or the KIM is faulty

Breakdown: the boiler is stopped GB162, GB172i
EH
262

The burner control unit or the KIM is faulty

Breakdown: the boiler is stopped GB162

The boilers that show this code

What our technician checks

  • The wiring and connectors of the burner control unit or the control unit, correctly reconnected
  • A reset of the control unit (GB172i)
  • The burner control unit or the control unit, replaced if necessary

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

262

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.