Temperature sensor: impossible value
Breakdown: the boiler is stopped
The boiler reads an impossible value from a temperature sensor (return or flow): below -5 °C, above +130 °C, or an interrupted contact. For safety, the boiler locks out and will only restart after a reset.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show CY?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code CY
The small number shown beside the code tells which.
The contacts of the return temperature sensor are open (interrupted)
Controller receives impermissible values from the return temperature sensor
Controller receives impermissible values from the return temperature sensor
Burner control unit receives impermissible values from the flow sensor
Flow temperature sensor fault (short circuit)
The boilers that show this code
What our technician checks
- The continuity of the connecting cable and the sensor
- The sensor resistance, measured and compared with the manufacturer's table, and any short circuit in the cable
- The wiring, connectors and operation of the return sensor, replaced if necessary (GB162)
- The water pressure, bleeding and water flow rate of the system (GB162)