Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
A61

Circuit 1: outdoor sensor or two master controllers

Blocking: it retries by itself

On a Logatherm or Bosch Compress heat pump (HMC300, HMC310 or HPC410 control), A61 concerns heating circuit 1 and the number next to it tells what it is about: the outdoor temperature sensor is faulty and the controller puts the heating into standby mode (1037), or the system has two master control units, whereas the room unit of this circuit should be registered as a remote control (1081). The system keeps running as far as possible.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show A61?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code A61

The small number shown beside the code tells which.

A61
1037

Outdoor temperature sensor faulty, heating standby mode active

Blocking: it retries by itself HMC300, HMC310, HPC410
A61
1081

Two master control units in the system

Blocking: it retries by itself HMC300, HMC310, HPC410

What our technician checks

  • The configuration, which needs an outdoor sensor (1037)
  • The cable between the controller and the outdoor sensor, and corroded terminals in the sensor housing (1037)
  • The outdoor sensor checked against the table, and the voltage at its terminals on the controller (1037)
  • The system-level settings: the room unit registered as the remote control of circuit 1 (1081)

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.