Flame detected during pre-purge
Breakdown: the boiler is stopped
On KB195i and KB195i.2 oil boilers, the flame detector sees a flame signal during the burner pre-purge. For safety, the boiler locks out and will only restart after a reset.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 6Y?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 6Y
The small number shown beside the code tells which.
Flame signal during pre-purge
The boilers that show this code
What our technician checks
- The position of the flame sensor, and stray light
- The flame sensor: removed and darkened, start attempt, replaced if fault Fd/510 appears
- The solenoid valve, replaced if necessary
- The ignition element, correctly fitted if fault EA/511 appears
- The sensor contact and the burner control unit connector; sensor or burner control unit replaced if necessary