Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
6Y

Flame detected during pre-purge

Breakdown: the boiler is stopped

On KB195i and KB195i.2 oil boilers, the flame detector sees a flame signal during the burner pre-purge. For safety, the boiler locks out and will only restart after a reset.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 6Y?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 6Y

The small number shown beside the code tells which.

6Y
510

Flame signal during pre-purge

Breakdown: the boiler is stopped KB195i, KB195i.2

The boilers that show this code

What our technician checks

  • The position of the flame sensor, and stray light
  • The flame sensor: removed and darkened, start attempt, replaced if fault Fd/510 appears
  • The solenoid valve, replaced if necessary
  • The ignition element, correctly fitted if fault EA/511 appears
  • The sensor contact and the burner control unit connector; sensor or burner control unit replaced if necessary

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.